4-3
Manually Setting Data Links
4-3-4 Creating
Data
Link Tables Offline
Node Editing Window (Edited Node Address: Node 01)
Function
(1)
Indicates that 20 words (D00000 to
D00019) from a remote node (node 03)
are received into the area starting from
CIO 01000 (i.e., CIO 01000 to CIO
01019) at the local node (node 01).
(2)
Indicates that 30 words starting from
CIO 01020 (i.e., CIO 01020 to CIO
01049) from the local node (node 01)
are sent to a remote node.
Indicates that the node refresh sequence
(1)
(2)
(3)
Address at local node
Address at remote node
(3)
Indicates that 40 words (CIO 00200 to
CIO 00239) from a remote node (node
02) are received into the area starting
from CIO 01050 (i.e., CIO 01050 to CIO
01089) at the local node (node 01).
Note
It is also possible to display the Node Editing Window in list format, as before.
Select
View - Show in List
from the menu. The change will go into effect the next
time the window is opened.
Node Editing
window
Setting Size (Send or Receive) and Offset
•
The send size can be set for the local node row by double-clicking in the Size cell.
(The default is the size set by the Datalink Wizard.) For remote node rows, the
receive size can be set. (The default is the entire send size from remote nodes.)
•
The reception offset can be set by double-clicking the Offset cell. (The default is 0.)
Size and offset can be set.
Automatically displayed.
4-19
Summary of Contents for CX-INTEGRATOR - V1.1
Page 1: ...OPERATION MANUAL CX Integrator Ver 1 1 SYSMAC CXONE AL C E Cat No W445 E1 02...
Page 2: ...CXONE AL C E CX Integrator Ver 1 1 Operation Manual Revised November 2005...
Page 3: ...iv...
Page 5: ...vi...
Page 13: ...xiv...
Page 120: ...Communications Section 3 Routing Tables This section describes how to set the routing tables 3...
Page 200: ...Communications Section 5 Ethernet This section describes the operations specific to Ethernet 5...
Page 328: ...Appendices A...
Page 336: ......