4-4
Automatically Set Data Links
4-4-2
Controller Link Automatic Setup
Equality Layout (Previous Method)
This is the previous automatic data link type where all nodes are allocated the same sizes of data
links.
A
H
(1)
B
(2 )
(6)
(5)
(3)
D
E
F
C
(4)
Settings Common to All Automatic Data Link Types
No.
Item
Description of function
A Generation
Type
Select
Automatic
. (If
Manual
is selected, data links will be
run using data link tables set separately.)
B Power
Up
Run State
Select
Start
to automatically start data links when power is
turned ON to the PLC.
C Close Closes
the
Automatic Datalink
Dialog Box.
D
Read
Reads the settings from the PLC.
E
Write
Writes the settings to the PLC.
(If the
Power Up Run State
is set to
Start
, the data links
will start running when the settings are written to the PLC.)
F Help
Displays
help.
G Automatic
Datalink
Type
Select the type of data links to be automatically set up
from the following.
Equality Layout (Previous method)
Common Type (1:N settings)
1 to 1 Type (1:N settings)
Chain Type (1:N settings)
H
Result
The status is displayed when the Read or Write Button is
clicked.
Equality Layout Settings
1
4
1
2
2
3
1
1
3
4
3
4
2
3
4
2
1
4
1
2
2
3
1
1
3
4
3
4
2
3
4
2
(5) Participating nodes
Area 1
Area 1
(1) Area and Start Word
(2) Size
(Same as (2).)
(Same as (2).)
(Same as (2).)
Area 2
(3) Area and Start Word
Area 2
(4) Size
(Same as (4).)
No. Item
Description
of
function
(1)
Area and Start Word
for Area 1
Set the area and the start data link word
to use for area 1.
(2)
Size of Area 1
Set the send size per node for area 1.
(3)
Area and Start Word
for Area 2
Set the area and the start data link word
to use for area 2.
(4)
Size of Area 2
Set the send size per node for area 2.
(5)
Nodes
Set the nodes to participate in the data
links.
(6)
Status start word
Set the first word to store data link status.
(If 0 words is set, the default area will be
used.)
Features of Equality Layout
•
The send data sizes is the same for all nodes for each area.
•
Area 1 is selected from the bit-access areas (e.g., CIO Area) and area 2 is
selected from word-access areas (e.g., DM Area).
•
Data link areas are allocated in ascending order of node addresses.
•
Data link participation can be specified for each node.
•
The same data link areas are shared by all nodes participating in the data links.
4-44
Summary of Contents for CX-INTEGRATOR - V1.1
Page 1: ...OPERATION MANUAL CX Integrator Ver 1 1 SYSMAC CXONE AL C E Cat No W445 E1 02...
Page 2: ...CXONE AL C E CX Integrator Ver 1 1 Operation Manual Revised November 2005...
Page 3: ...iv...
Page 5: ...vi...
Page 13: ...xiv...
Page 120: ...Communications Section 3 Routing Tables This section describes how to set the routing tables 3...
Page 200: ...Communications Section 5 Ethernet This section describes the operations specific to Ethernet 5...
Page 328: ...Appendices A...
Page 336: ......