4-3 Manually
Setting Data Links
4-3-9
Creating, Reading, and Writing CSV Files (Saving)
Tag name
Description
Set value
<start-type>
(Link Area 1
type)
Specify the area type for Link
Area 1.
Same as for status area type.
<start-ch>
(Link Area 1 start
address)
The beginning word for Link
Area 1.
Same as for status area start
address.
Node
No.
Node address
The node
address for
linking at
Link Area 1.
1 to 62
Link
start
address
Link word
The
beginning
link word for
Link Area 1.
Set the link start a link
size for the above link node.
Link size
Size (Unit:
words)
The link size
for Link Area
1.
Set any value.
(3) <area1>
<link-
area>
Offset
size
Offset The
offset
size for Link
Area 1.
Set any value. If no offset is
required, set 0.
<start-type>
(Link Area 2
type)
The area type for Link Area 2.
Same as for status area type.
<start-ch>
(Link Area 2 start
address)
The beginning word for Link
Area 2.
Same as for status area start
address.
Node
No.
Node address
The node
address for
linking at
Link Area 2.
1 to 62
Link
start
address
Link word
The
beginning
link word for
Link Area 2.
Set the link start a link
size for the above link node.
Link size
Size (Unit:
words)
The link size
for Link Area
2.
Set any value.
(4) <area2>
<link-
area>
Offset
size
Offset The
offset
size for Link
Area 2.
Set any value. If no offset is
required, set 0.
4-30
Summary of Contents for CX-INTEGRATOR - V1.1
Page 1: ...OPERATION MANUAL CX Integrator Ver 1 1 SYSMAC CXONE AL C E Cat No W445 E1 02...
Page 2: ...CXONE AL C E CX Integrator Ver 1 1 Operation Manual Revised November 2005...
Page 3: ...iv...
Page 5: ...vi...
Page 13: ...xiv...
Page 120: ...Communications Section 3 Routing Tables This section describes how to set the routing tables 3...
Page 200: ...Communications Section 5 Ethernet This section describes the operations specific to Ethernet 5...
Page 328: ...Appendices A...
Page 336: ......