48
I/O Data Allocations
Section 4-3
Input
(cont’d)
n + 8
n + 18
15
Results
Informa-
tion
Head Error Flag
(Error Code: 7C)
Turns ON when an error occurs because a
R/W Head is not connected.
Turns ON when the 24-V power is not cor-
rected supplied to the R/W Head.
14
Verification Error
Flag
(Error Code: 71)
Turns ON when data cannot be written cor-
rectly to the Data Carrier (only when verifi-
cation is specified).
13
Data Carrier
Address Error
Flag
(Error Code: 7A)
Turns ON when execution is not possible
because the processing address is not
specified correctly.
12
Data Carrier Com-
munications Error
Flag
(Error Code: 70)
Turns ON when communications cannot be
completed normally because an error
occurred in communications with the Data
Carrier.
11
Write Protection
Error Flag
(Error Code: 7D)
Turns ON when an attempt is made to write
to a write-protected area.
Turns ON when the Data Carrier is not an
applicable model.
10
Data Carrier Miss-
ing Error Flag
(Error Code: 72)
Turns ON when the communications specifi-
cation is designated as a trigger but there is
no Data Carrier in the R/W Head’s commu-
nications area.
Turns ON when there is no Data Carrier in
the R/W Head’s communications area
before the auto wait time elapses.
06 to 09
---
Not used
05
Battery Warning
Flag
(Error Code: 7B)
Turns ON when an error occurs outside of
the write area.
Turns ON when a battery warning occurs.
04
Status Flag
(Error Code: 76)
Turns ON for a Calculation Write command
if addition results in an overflow or subtrac-
tion results in an underflow.
Turns ON when a difference is found for the
verification results for a Data Check com-
mand.
Turns ON when the specified number of
writes is exceeded for a Number of Writes
Control command.
Turns ON for a Copy command if an error
occurs when writing after data has been
read.
02 and
03
---
Not used
01
Data Storage Area
Specification Error
Turns ON when processing specified in data
storage area cannot be executed.
00
Command Error
Turns ON when there is an error in the set-
ting for the Command, Communications
Specification, Processing Address, or Num-
ber of Processing Bytes.
Turns ON when an attempt is made to exe-
cute the Copy command for the CS1W-
V600C11/CJ1W-V600C11.
n + 9
n + 19
00 to 15 Monitor
Processing
Results Monitor
Normal end: Processing time (1 to 9999
×
10 ms)
Max. error: 10 ms
Error end: “E0” + “Error Code”
Cleared when the power supply is turned
ON or command execution starts.
I/O
Word address
Bit No.
Type
Bit name
Description
Head 1 of CS1W-
V600C11, CS1W-
V600C12, CJ1W-
V600C11, or
CJ1W-V600C12
Head 2 of CS1W-
V600C12 or
CJ1W-V600C12
Summary of Contents for CJ - 12-2004
Page 2: ...SYSMAC CS CJ Series ID Sensor Units Operation Manual Revised December 2004...
Page 3: ...iv...
Page 11: ...xii...
Page 55: ...36 Connections and Wiring Section 3 4...
Page 69: ...50 I O Data Allocations Section 4 3...
Page 91: ...72 Data Check Section 5 7...
Page 141: ...122 Sample Programming Appendix B...
Page 147: ...128 Revision History...