119
Sample Programming
Appendix B
Unit Settings Example
First word allocated to Unit in DM Area: m = (100
×
77) = D27700
First Word Allocated to Unit in CIO Area: n = CIO 2000 + (10
×
77) = CIO 2770
---: Ignored.
Item
Setting
Setting location
Unit No.
77
Unit’s front panel unit number switches: 77
Operating modes
Normal Mode
Unit’s front panel communications test switch: OFF
System Settings
Operating mode switch enabled
Write verification setting
Communications mode: Communications
distance priority
Set in the Special I/O Unit words in DM Area.
Auto Wait Time Set-
ting
Infinite
Command
Copy
Set in the Special I/O Unit Area.
Communications
specification
Single auto
Read start address
0020 (hex)
Number of read/write
bytes
16 bytes
Write start address
0010 (hex)
DM
address
Contents
Meaning
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
D27700
0
0
0
0
Not used
Communications
test switch enabled
Verification for writ-
ing
Communications
mode: Distance
D27701
0000
Auto Wait Time Setting
Word
address
Contents
Meaning
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
CIO 2771
09
1
0
Command code
Communications
specification
---
CIO 2772
00
20
First processing address
CIO 2773
00
10
Number of processing bytes
CIO 2774
00
00
---
CIO 2775
0
0
00
---
---
---
CIO 2776
00
10
Command option
Summary of Contents for CJ - 12-2004
Page 2: ...SYSMAC CS CJ Series ID Sensor Units Operation Manual Revised December 2004...
Page 3: ...iv...
Page 11: ...xii...
Page 55: ...36 Connections and Wiring Section 3 4...
Page 69: ...50 I O Data Allocations Section 4 3...
Page 91: ...72 Data Check Section 5 7...
Page 141: ...122 Sample Programming Appendix B...
Page 147: ...128 Revision History...