42
Initial Settings Data
Section 4-2
4-2-2
DM Area Contents (Same for Normal or Test Mode)
The following initial settings are set in the words allocated in the DM Area.
Note
First word allocated to Unit in DM Area: m = 100
×
unit No.
DM Area address
Bit No.
Type
Description
Setting
Reference
Head 1 of
CS1W-
V600C11,
CS1W-
V600C12,
CJ1W-
V600C11,
or CJ1W-
V600C12
Head 2 of
CS1W-
V600C12
or CJ1W-
V600C12
m
m + 100
12 to 15
System
Settings
Not used
---
---
08 to 11
Operating mode switch
setting
0: Enabled (1-digit BCD)
1: Disabled (1-digit BCD)
Page 56
04 to 07
Setting for write verifica-
tion
0: Verification (1-digit
BCD)
1: No verification (1-digit
BCD)
Page 56
00 to 03
Communications mode
setting
0: Communications dis-
tance priority (1-digit
BCD)
1: Communications time
priority (1-digit BCD)
Page 57
m + 1
m + 101
00 to 15
Auto Wait
Time Set-
ting
The Data Carrier timeout
time when the Communi-
cations Specification is
single auto or repeat
auto. A Data Carrier
Missing Error will be
returned if this value is
exceeded.
0001 to 9999 (
×
0.1 s)
0000: Infinite
Page 58
Summary of Contents for CJ - 12-2004
Page 2: ...SYSMAC CS CJ Series ID Sensor Units Operation Manual Revised December 2004...
Page 3: ...iv...
Page 11: ...xii...
Page 55: ...36 Connections and Wiring Section 3 4...
Page 69: ...50 I O Data Allocations Section 4 3...
Page 91: ...72 Data Check Section 5 7...
Page 141: ...122 Sample Programming Appendix B...
Page 147: ...128 Revision History...