57
System Settings and Auto Wait Time Setting
Section 5-3
Communications Mode
Setting
This setting is valid only when accessing EEPROM (battery-free) Data Carri-
ers. It is ignored for SRAM (built-in battery) Data Carriers. For details, refer to
the user manual for the R/W Heads and Data Carriers.
Note
1.
First word allocated to Unit in DM Area: m = 100
×
unit No.
2.
Always turn the power supply to the PLC OFF and ON or turn ON the Spe-
cial I/O Unit Restart Bit after changing settings in the DM Area from a Pro-
gramming Device. DM Area setting data is transferred to Special I/O Units
only when the power supply is turned ON or the Special I/O Unit Restart
Bit is turned ON.
DM Area address
Bit No.
Description
Default
Head 1 of
CS1W-
V600C11,
CS1W-
V600C12,
CJ1W-
V600C11,
or CJ1W-
V600C12
Head 2 of
CS1W-
V600C12
or CJ1W-
V600C12
m
m + 100
00 to
03
0
Communicate using the Com-
munications Distance Priority
Mode.
0
(distance
priority)
1
Communicate using the Com-
munications Time Priority
Mode.
Summary of Contents for CJ - 12-2004
Page 2: ...SYSMAC CS CJ Series ID Sensor Units Operation Manual Revised December 2004...
Page 3: ...iv...
Page 11: ...xii...
Page 55: ...36 Connections and Wiring Section 3 4...
Page 69: ...50 I O Data Allocations Section 4 3...
Page 91: ...72 Data Check Section 5 7...
Page 141: ...122 Sample Programming Appendix B...
Page 147: ...128 Revision History...