![background image](http://html1.mh-extra.com/html/omron/cj-12-2004/cj-12-2004_manual_740789016.webp)
xvii
Precautions for Users of the C200H-IDS01(-V1)
6
• Use crimp terminals for wiring. Do not connect bare stranded wires
directly to terminals.
• Observe the following precautions when wiring cables.
• Do not bend the cables past their natural bending radius.
• Do not pull on the cables.
• Do not place heavy objects on top of the cables.
• Check terminal blocks sufficiently before mounting them.
• Be sure that the terminal blocks, Memory Units, expansion cables, and
other items with locking devices are properly locked into place. Improper
locking may result in malfunction.
• Check the user program for proper execution before actually running it on
the Unit. Not checking the program may result in an unexpected opera-
tion.
• Check all wiring carefully before turning ON the power supply.
• Confirm that no adverse effect will occur in the system before attempting
any of the following. Not doing so may result in an unexpected operation.
• Changing the operating mode of the PLC.
• Force-setting/force-resetting any bit in memory.
• Changing the present value of any word or any set value in memory.
• Before touching a Unit, be sure to first touch a grounded metallic object in
order to discharge any static build-up. Not doing so may result in malfunc-
tion or damage.
• Stop operation and turn OFF the power supply immediately if you smell
any unusual odors, if the surface of the Unit become abnormally hot, if
smoke appears, of if the Unit seems unusual in any other way.
6
Precautions for Users of the C200H-IDS01(-V1)
The CS1W-V600C11, CS1W-V600C12, CJ1W-V600C11, and CJ1W-
V600C12 (CS/CJ-series) ID Sensor Units
cannot
be controlled with program-
ming written for the C200H-IDS01 or C200H-IDS01-V1 ID Sensor Unit. Refer
to
SECTION 4 Data Exchange with the CPU Unit
for details. This section
describes the main differences between these Units.
Command Settings
The CS/CJ-series ID Sensor Units allow the Data Carrier processing com-
mand and Data Carrier communications method (i.e., the communications
specification) to be set separately. Commands written for the C200H ID Sen-
sor Units cannot be used without modification. Refer to
SECTION 4 Data
Exchange with the CPU Unit
for details on designating commands and com-
munications methods.
Summary of Contents for CJ - 12-2004
Page 2: ...SYSMAC CS CJ Series ID Sensor Units Operation Manual Revised December 2004...
Page 3: ...iv...
Page 11: ...xii...
Page 55: ...36 Connections and Wiring Section 3 4...
Page 69: ...50 I O Data Allocations Section 4 3...
Page 91: ...72 Data Check Section 5 7...
Page 141: ...122 Sample Programming Appendix B...
Page 147: ...128 Revision History...