30
Linear Mode
Section 4-3
A range consists of lower and upper limits and output pattern, and uses five
words. The lower limit uses two words, the upper limit uses two words, and
the output pattern uses one word. Up to 16 ranges are available.
The upper and lower limits can be set within a range of –8,388,608 and
8,388,607.
The following is an example of range 0.
Lower Limit
BCD
Range: –8,388,608 to 8,388,607
Hexadecimal
Range: 800000 to FFFFFF (–8,388,608 to –1) and 000000 to 7FFFFF (0 to
8,388,607)
Upper Limit
The configuration of the upper limit is the same as that of the lower limit.
Replace word m+16 with m+18 and word m+15 with m+17.
Lower limit
Upper limit
Output pattern
Range 0
to
to
to
Range 1
Range 15
to
Lower limit
Upper limit
Output pattern
Lower limit
Upper limit
Output pattern
Sign
Set to 0.
Summary of Contents for C200H-CT021
Page 1: ...C200H CT021 High speed Counter Unit Operation Manual Revised December 2000 ...
Page 2: ...iv ...
Page 4: ...vi ...