108
Program Example for Gate Mode
Section 9-5
Program Example
KEEP
00000
SUBL(55)
112
DM0000
DM0004
DIFD(14)03000
11600
CLC(41)
25313
03000
25504
CLC(41)
25313
S
R
S
R
KEEP
00002
SUBL(55)
112
DM0002
DM0004
03000
25504
S
R
00001
00000 00002 11600
11600
11600
(Counting)
(Always ON)
(CY Flag)
(CY Flag)
(Always ON)
Checks whether count value is
≥
lower limit
Outputs if dimensions are too small.
Checks whether count value is
≤
upper limit.
Outputs if dimensions are too large.
Outputs if dimensions are within standards.
Lower limit
Upper limit
DM 0000
DM 0001
DM 0002
DM 0003
DM 0004
DM 0005
Work
Comparison Data Areas
Output Results
00000 ON
00001 ON
00002 ON
Dimensions too small
Dimensions correct
Dimensions too large
Summary of Contents for C200H-CT021