50
DM Area Allocation in Linear and Circular Modes
Section 5-2
m+6
00 to 15 Ranges assigned to counter 2 (1: Enabled; 0: Disabled)
Bits 00 to 15 correspond to ranges 0 to 15.
m+7,
m+8
00 to 15
m+9,
m+10
00 to 15 Max. count value of counter 2 (in circular mode only)
m+11,
m+14
---
Not used.
m+15,
m+16
00 to 15
m+17,
m+18
00 to 15
Word
Bit
Function
Max. count value of counter 1 (in circular mode only)
BCD
Range: 1 to 65,535
Hexadecimal
Range: 0001 to FFFF
In the above example, the maximum value of counter 1 is specified. Words m+10 and m+9 are
used for counter 2.
Set to 0.
Set to 0.
Lower limit of range 0
BCD
Range:
−
8,388,608 to 8,388,607
Hexadecimal
Range: 800000 to FFFFFF (
−
8,388,608 to
−
1) and 000000 to 7FFFFF (0 to 8,388,607)
Set to 0.
Sign
Upper limit of range 0
BCD
Range:
−
8,388,608 to 8,388,607
Hexadecimal
Range 800000 to FFFFFF (
−
8,388,608 to
−
1) and 000000 to 7FFFFF (0 to 8,388,607)
Set to 0.
Sign