81
Program Example for Linear Mode
Section 7-6
DM Settings
Example:Counter 1
Program Example
The process display lamps are directly turned ON and OFF by external out-
puts 0 to 3.
DM 1115
DM 1116
DM 1117
DM 1118
DM 1119
DM 1120
DM 1121
DM 1122
DM 1123
DM 1124
DM 1125
DM 1126
DM 1127
DM 1128
DM 1129
DM 1130
DM 1131
DM 1132
DM 1133
DM 1134
DM 1100
DM 1101
DM 1105
Linear mode, external NPN outputs, BCD data,
offset phase pulse inputs x 1, reset mode 10
Enabled ranges: 0 to 3
Range 0
1000 to 1200 (in process station 1)
External output 0: ON
Internal output: 0101 (bits 08 and 00: ON)
Range 1
2500 to 2900 (in process station 2)
External output 1: ON
Internal output: 0202 (bits 09 and 01: ON)
Range 2
5000 to 9500 (at the gripper hand position)
External output 2: ON
Internal output: 0304 (bits 09, 08, and 02: ON)
Range 3
9501 to 8388607 (past the gripper hand position)
External output 3: ON
Internal output: 0408 (bits 10 and 03: ON)
11909
11910
11000
11007
Station 1
processing
11909
11908
11910
11908
11909
11910
11908
11910
11909
11908
Gripper pro-
cessing
Cycle and
processing
Station 2
processing
While the start switch is ON, external outputs are
enabled and the counter continues counting.
When the present counter value is within range 0,
processing is carried out at station 1.
When the present counter value is within range 1,
processing is carried out at station 2.
When the present counter value is within range 2,
the gripper hand operations are carried out.
When the present counter value is within range 3,
the processing at the end of the cycle is carried out.
11908
11909
11910
Internal outputs:
Turned ON or OFF according to the settings of ranges 0 to 3. Therefore
the location of each workpiece can be found and the workpiece can be
processed properly.
Start switch