![background image](http://html1.mh-extra.com/html/omron/c200h-ct021/c200h-ct021_operation-manual_741966144.webp)
138
Data Area Allocation
Appendix B
IR Bit Allocation
(n = 100 + 10 x Unit No.) or
(n = 400 + 10 x (Unit No. –
10) if Unit No. is A to F
)
Bit
Word (Output)
n
n+1
00
Start/Stop
Valid value range number
Each bit
1: Enabled
0: Disabled
01
Change ranges for counter 1
02
Change ranges for counter 2
03
Data transfer
04
RESET Counter 1
05
RESET Counter 2
06
Read error
07
ENABLE External Output
08
0
Forced external output
1: ON, 0: OFF
09
1
10
2
11
3
12
4
13
5
14
6
15
7