Program Example for Circular Mode
Section 7-7
Operation
The control timing of a device connected to the shaft drive of the motor is
detected by the incremental encoder, and outputs are controlled according to
the angle of rotation.
Offset phase inputs multiplied by 4 are input to the encoder.
BCD data is used in the system.
The counter is reset at the rising edge of external counter input Z and Internal
Reset Flag. (Mode 6)
Switch Settings
The unit number of the High-speed Counter Unit is set to 1 and the High-
speed Counter Unit will have NPN external outputs.
Wiring
Connect the A-, B-, and Z-phase outputs of the incremental encoder to
counter 1 inputs A, B, and Z.
Connect external outputs 1, 6, and 7 the control component of the system.
DM Settings
Program Example
DM 1115
DM 1116
DM 1117
DM 1118
DM 1119
DM 1120
DM 1121
DM 1122
DM 1123
DM 1124
DM 1125
DM 1126
DM 1127
DM 1128
DM 1129
DM 1100
DM 1101
DM 1105
DM 1107
DM 1108
Circular mode, external NPN outputs, BCD data,
offset phase pulse inputs x 4, reset mode 6
Enabled ranges: 0 to 2
Maximum count value: 4,999
Range 0
1000 to 1010
External output 7: ON
Range 1
4300 to 200 (via 0)
External outputs 6 and 1: ON
Range 2
600 to 3100 (via 0)
External outputs 7 and 6: ON
11000
11007
Start switch
11004
11601
11004
While the start switch is ON, external
outputs are enabled and the counter
continues counting.
Reset switch
Counter input Z
The counter is reset at the rising
edge of the first counter input Z after
the counter reset switch is pressed.