Page: 143
Service Guide OF1000
Chapter 4 Failure & Repair Analysis
RAP 12: High-Speed Modem Test Failure
START
Place the leads of your multimeter across the RJ-11C data terminals, TIP and RING (you will be
measuring rms voltage).
Perform the H-MODEM SEND TEST (transmitter) and the H-MODEM RECEIVE TEST (receiver).
NOTE:
You will need two Okifaxes to perform this procedure. However, they need not be at the same
location.
Are you troubleshooting the transmitting Okifax?
NO Go to POINT - A
YES Does the multimeter read approximately .27 volts rms?
YES Although the Okifax 1000 appears to be transmitting, the validity of the data transfer
cannot be assured by this voltage measurement. If you are encountering communication
error, replace the following in the order listed.
(1) MCNT-150 board
(2) NCU-U board
(3) LINE-JU board
NO Place the leads of your multimeter across CN7 pins 1 and 4 of the NCU board.
Does the multimeter read approximately .27 volts rms?
YES Replace the NCU-U board.
Is the problem resolved?
YES End of procedure.
NO Replace the MCNT-150 board.
NO Is + 12 vdc present on CN1 pin 14 of the MCNT-150
board and is - 12 vdc present on CN1 pin 15 of the MCNT-15 board?
NO Replace the PWU-150.
Is the problem resolved?
Summary of Contents for OF1000
Page 146: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Page 185: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Page 208: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Page 260: ...Partner Exchange BPX for any updates to this material http bpx okidata com...