Chapter 4 Failure & Repair Analysis
4.8 RESETS
The following Okifax 1000 counters must periodically be reset.
· Toner Counter
· Drum Counter
· Fuser Counter
WARNING:
Although there is a PRINTER COUNTER RESET Option available, DO NOT reset the
counter. This counter is used to keep track of the total number of printed pages.
You must do the following in order to RESET any of the counters.
· Power ON the Okifax 1000.
· Set the Service Bit (TECHNICAL FUNCTION 27) to ON.
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business
Partner Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)