Page: 176
Service Guide OF1000
Chapter 4 Failure & Repair Analysis
4.6.07 Multi-Frequency Tone Test
This test is used to verify the operation of the multi-frequency touch-tone signals from the LINE
terminal.
Refer to RAP 13
if the Multi-Frequency Tone Test should fail.
Procedure
1. Press
SELECT FUNCTION.
2. Press
COPY
twice.
3. Press
LEFT ARROW
twice.
4. Press the
"7"
Key on the ten-key pad.
5. Press
LEFT ARROW
.
6. Press each key of the ten-key pad keys.
The multi-frequency signal of the key will be continuously sent after each key is pressed.
7. Press
STOP
four times to exit the test.
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business
Partner Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)