5. Press the
"2"
Key on the ten-key pad.
6. Load a sheet of white letter size paper in the document feed area.
The following message will be displayed.
SENSOR CALIBRATION
YES NO
7. Press
LEFT ARROW.
NOTE:
The Okifax 1000 will calibrate the CIS and display the following sequence of messages.
SENSOR CALIBRATION
CALIBRATING
SENSOR CALIBRATION
RESULT = OK
SCANNING CHECK
YES NO
NOTE:
Refer to RAP 09
should the CIS calibration fail.
Technical Function 25 (Sensor Calibration) will automatically be set to OFF upon completion of
the sensor calibration.
8. Press
RIGHT ARROW
to remove the document.
9. Press
STOP
three times to exit the test.
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business
Partner Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)