Page: 86
Service Guide OF1000
Chapter 3 Maintenance & Disassembly
3.2.20 Control Panel Assembly
1. Power OFF the unit and detach the AC power cord.
2. Open the control panel assembly (1).
3. Remove the two screws (2).
4. Disconnect the connector (3).
5. Remove the screw (4).
6. Remove the control panel assembly.
NOTE:
The one touch cover and one touch sheet can be removed without removing the control panel
assembly.
The Cable: OPE-MCNT connects the board (OPE-150) to CN9 of the board (MCNT).
P/N 52067801 Cover: One-Touch Label Covers
RSPL B.2.03
P/N 58233501 Labels: One-Touch Dial
RSPL B.2.03
P/N 50102101 Panel: Control Panel Assembly
RSPL B.2.03
P/N 56628701 Cable: OPE-MCNT
B.2.16
Copyright 1997, Okidata, Division of OKI America, Inc. All rights reserved. See the OKIDATA Business
Partner Exchange (BPX) for any updates to this material. (http://bpx.okidata.com)
Summary of Contents for OF1000
Page 146: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Page 185: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Page 208: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Page 260: ...Partner Exchange BPX for any updates to this material http bpx okidata com...