Page: 183
Service Guide OF1000
Chapter 4 Failure & Repair Analysis
Facsimile Control Field Conversion Table
This chart shows all facsimile control field (FCF) signals which are needed to analyze the printed
out protocol dump data.
Some signals have two different hexadecimal codes, in accordance with the calling party or called
party.
Abbreviation
Hexadecimal Codes
Description of Function
NSF
04
Non-Standard Facilities
CSI
02
Called Subscriber Identification
DIS
01
Digital Identification Signal
NSC
84
Non-Standard Facilities Command
CIG
82
Calling Subscriber Identification
DTC
81
Digital Transmit Command
NSS
44 C4
Non-Standard Set-up
TSI
42 C2
Transmitting Subscriber Identification
DCS
41 C1
Digital Command Signal
CFR
21 A1
Confirmation to Receive
MCF
31 B1
Message to Confirmation
FTT
22 A2
Failure to Train
MPS
72 F2
Multi-Page Signal
EOM
71 F1
End of Message
EOP
74 F4
End of Procedure
RTP
33 N3
Retrain Positive
RTN
32 B2
Retrain Negative
PIP
35 B5
Procedure Interrupt Positive
PIN
34 B4
Procedure Interrupt-Negative
PRI-MPS
7A FA
Procedure Interrupt-MPS
PRI-EOM
79 F9
Procedure Interrupt-EOM
PRI-EOP
7C FC
Procedure Interrupt-EOP
DCN
AF DF
Disconnect
CRP
58 D8
Command to Repeat
CTC
48 C8
Continue to Correct
CTR
23 A3
Response to End of Transmission
EOR
73 F3
End of Transmission
ERR
38 B8
Response to End of Retransmission
FCD
60
Facsimile Coded Data
PPS
7D FD
Partial Page Signal
PPR
3D BD
Partial Page Request
RCP
61
Return to Control for Partial Page
RNR
37 B7
Receive Not Ready
RR
76 F6
Receive Ready
Summary of Contents for OF1000
Page 146: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Page 185: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Page 208: ...Partner Exchange BPX for any updates to this material http bpx okidata com...
Page 260: ...Partner Exchange BPX for any updates to this material http bpx okidata com...