Page: 89
Service Guide OF1000
Chapter 3 Maintenance & Disassembly
3.2.23 Pinch Roller
1. Perform these procedures:
3.2.01
3.2.15
3.2.20
3.2.21
2. Using a needle nose pliers, remove the spring (1).
3. Remove the pinch roller (2).
4. Remove the ADF tension arm (Not shown).
5. Remove the ADF back-up plate (Not shown).
6. Remove the pinch roller spring (upper) (Not shown).
NOTE:
Cleaning
Clean the pinch roller as necessary.
Refer to Section 3.4 of this Service Handbook for
cleaning details
.
P/N 50925501 Spring: ADF
RSPL B.2.15
P/N 53061201 Arm: ADF Tension
RSPL B.2.15
P/N 53339801 Plate: ADF Back-Up
RSPL B.2.15
P/N 50406201 Roller: Pinch
RSPL B.2.15
P/N 51112501 Roller: Pinch Shaft
RSPL B.2.15
P/N 50925701 Spring: Pinch Roller (Upper)
RSPL B.2.15