![background image](http://html1.mh-extra.com/html/okidata/of1000/of1000_service-manual_3619431160.webp)
Page: 109
Service Guide OF1000
Chapter 3 Maintenance & Disassembly
3.2.43 Fuser Unit Assembly
WARNING:
Allow the fuser unit assembly to cool before servicing.
1. Perform these procedures:
3.2.01
3.2.02
3.2.09
3.2.15
3.2.16
3.2.42
2. Remove the four screws (1).
3. Remove the fuser unit assembly (2).
NOTE:
Installation
Reset the fuser counter when installing a new fuser unit.
Refer to Section 4.8 of this Service
Handbook
for further details.
Lubrication
Lightly lubricate the fuser gear.
Refer to Section 3.5 of this Service Handbook for lubrication
details
.
P/N 50217501 Unit: Fuser Assembly (120V)