Check Power cord
▌
Your power supply is equipped with a 3-wire grounding type power cord; the third conductor being
the ground. The power supply is grounded only when the power line cord is plugged into an
appropriate receptacle. Do not operate your power supply without adequate cabinet ground connection.
Check Input AC Power Line
▌
You can operate your power supply from a nominal 198~242 V single phase AC power source
at 47 to 63 Hz. AC100V, 110V, 115V, 230V input power is optional.
Refer to chapter "1-2. Accessories & Options"
▌
In order to prevent the instrument severe damage from overload, fuse is built-in (1U, 2U products)
or braker(3U products) is installed rear side. If fuse also is broken or braker is turned down repeatedly
when power turns on, check the input power line or broken braker and then call to nearest
ODA Technologies A/S Center.
If products maximum output capacity is over 5KW, fuse will be replaced to Breaker.
- 14 -