3-2. Constant Current Operating (CC)
To set up the power supply for constant current (CC) operation, proceed as follows
▌
Turn on the power suppl
After turned on, check the power supply displays"**OUTPUT OFF**" Mode.
▌
Connect the DUT to output terminals.
▌
In order to set the limit value, press the LMT Key.
▌
Press the left key and move the under bar cursor to voltage value. In order to
increase or decrease the voltage value, turn the encoder switch CW or CCW.
Under the protection(OVP/UVL/OVL) setting state, voltage ca nnot be over
protection level. If the voltage value is over the protect ion setting value,
instrument "displays "PROTECTION LIMIT" message and volta ge will set to
protection level value
▌
In other to set the current value, use the right cursor key and encoder knob.
Under the protection(OVP/UVL/OVL) setting state, current ca nnot be over
protection level. If the voltage value is over the protect ion setting value,
instrument "displays "PROTECTION LIMIT" message and curre nt will set to
protection level value.
▌
If the all setting is finished, enable the output.(Press the output ON/OFF key
and then power supply changes to readback display from limit display
▌
CC lamp is on, CV lamp is off.
If lamp is reversed, check the voltage setting value is low.
If the voltage value is low, increase the current value limit.
≫ Related Remote Interface Command
APPLy{<voltage>,<current>}
VOLT{<voltage>|UP|DOWN}
CURR{<current>|UP|DOWN}
OUTP{OFF|ON}
OUTP OFF
Disable Output
Apply 2:
OUTP OFF
VOLT 10
Set the voltage to 10V
APPLY 10,5
Set 10
10V /5A
CURR 5
Set the current 5A
OUTP ON
OUTP ON
Enable Output
- 27 -
Disable Output
Enable Output
Apply 1: