Nortel Networks Confidential
1-1
Wireless Solutions
DualMode 800 Enclosure Maintenance Manual
MTX08
Equipment operation
1
In a DualMode 800 Enclosure, you can communicate with the Alarm Control
Unit (ACU), the Transmit Receive Unit (TRU) and the Multi-Channel Power
Amplifier (MCPA) by the use of an interface terminal or a computer. You can
use the handset on the DualMode Cell Site Monitor (DCSM) to program the
mobile unit and perform call through test.
This chapter describes the interface commands for configuring and
programming these units in the DualMode 800 Enclosure.
Alarm Control Unit
The MAINTENANCE (Local Terminal) port located on the front of the ACU
gives direct access to the ACU MPU board. You can use this interface to
configure and monitor the alarm input points and the control output contacts.
To access the ACU for local maintenance and monitoring, you need a VT100
(or equivalent) terminal with the following settings:
Stop bit control
1 bit
Word length
8 bits
Parity
none
BAUD rate
9600
Interface
RS-232C
If you cannot set the terminal to the settings listed, change the ACU
configuration by setting the local terminal switch (SW3) on the MPU board to
match your terminal settings. Refer to Table 5-4 for the settings of SW3 in the
DualMode 800 Enclosure Functional Description, 411-2051-100.
When
the terminal and ACU are set correctly, connect the terminal to the
MAINTENANCE port with a null modem cable. Power up the terminal, hold
the CONTROL key and press the Z key. A menu of options will appear on the
screen as shown in Figure 1-1.
Summary of Contents for DualMode 800
Page 2: ......
Page 4: ......
Page 6: ...vi Publication history Nortel Networks Confidential 411 2051 500 Draft 00 01 November 1999...
Page 82: ...2 20 Periodic maintenance 411 2051 500 Draft 00 01 November 1999...
Page 90: ...3 8 Test equipment and precautions 411 2051 500 Draft 00 01 November 1999...
Page 100: ...5 6 Master Oscillator tests 411 2051 500 Draft 00 01 November 1999...
Page 106: ...6 6 Antenna and transmission line tests 411 2051 500 Draft 00 01 November 1999...
Page 116: ...8 4 Alarm Control Unit ACU tests 411 2051 500 Draft 00 01 November 1999...
Page 138: ...10 2 ICRM tests 411 2051 500 Draft 00 01 November 1999...
Page 200: ...12 10 Enclosure maintenance 411 2051 500 Draft 00 01 November 1999...
Page 208: ...A 8 Appendix A Frequency table 411 2051 500 Draft 00 01 November 1999...
Page 215: ......