Performing tests using the DCSM in the directed mode
9-9
Wireless Solutions
DualMode 800 Enclosure
Maintenance Manual
MTX08
MTX CTT tests
MTX CTT (Cellular Terminal Tests) tests use the DCSM as a test mobile to
test AVCHs by looping around a tone generated by the MTX Trunk Test
Terminal (TTT). These tests measure the performance of the specified AVCH
and associated trunks. The performance criteria measurable are:
•
wireline trunk audio performance (loss) and associated noise
(MALT, MAHT)
•
wireless trunk RF performance (loss) and associated noise
(MRLT, MRHT)
•
forward and reverse RF strength performance (MRLP, MRLR)
•
system call set-up capability (MTRM, DTRM)
Naming conventions
All MTX trunk tests use a four letter acronym to describe the functionality of
the test. Each letter of the test acronym is explained in Table 9-1.
MTX Audio Low Test and MTX Audio High Test (MALT/MAHT)
This test does not require a DCSM. The MALT and MAHT test measures the
following MTX trunk parameters:
•
far-to-near-loss
•
loop loss
•
loop noise
Table 9-1
Naming convention of the MTX trunk tests
Letter #
Designation
1
M = MTX — test a MTX VCH trunk
D = DCCH — set-up VCH trunk
2
A = Audio — test the audio link of the trunk
(DCSM is not a requirement)
R = RF — test the RF link of the trunk
3
L = Low — use a low level tone for the test
H = High — use a high level tone for the test
4
T = Transmission — measure transmission loss and
noise
R = Receiver — measure the reverse RF power level
of the VCH
P = Power — measure the forward RF power level of
the VCH
Note:
DTRM and MTRM violate this naming convention.
Summary of Contents for DualMode 800
Page 2: ......
Page 4: ......
Page 6: ...vi Publication history Nortel Networks Confidential 411 2051 500 Draft 00 01 November 1999...
Page 82: ...2 20 Periodic maintenance 411 2051 500 Draft 00 01 November 1999...
Page 90: ...3 8 Test equipment and precautions 411 2051 500 Draft 00 01 November 1999...
Page 100: ...5 6 Master Oscillator tests 411 2051 500 Draft 00 01 November 1999...
Page 106: ...6 6 Antenna and transmission line tests 411 2051 500 Draft 00 01 November 1999...
Page 116: ...8 4 Alarm Control Unit ACU tests 411 2051 500 Draft 00 01 November 1999...
Page 138: ...10 2 ICRM tests 411 2051 500 Draft 00 01 November 1999...
Page 200: ...12 10 Enclosure maintenance 411 2051 500 Draft 00 01 November 1999...
Page 208: ...A 8 Appendix A Frequency table 411 2051 500 Draft 00 01 November 1999...
Page 215: ......