Nortel Networks Confidential
DualMode Cell Site Monitor (DCSM)
1-15
Wireless Solutions
DualMode 800 Enclosure Maintenance Manual
MTX08
Use the arrow key to scroll to the Primary First Paging Channel (1STCHP1)
display. Enter the Control Channel (CCH) number for your cellular band,
Channel 333 for A system or channel 334 for B system. The CCH must be a
standard CCH although NAM4 can be programmed to use a non-standard
CCH. A non-standard CCH is generally for bench-testing to prevent
interference with local cel1site CCHs. (333 for A, or 334 for B system)
Use the arrow key to scroll to the Secondary First Paging Channel
(1STCHP2) display. Enter the three digit second control channel number of
the cell site, if any. (708 for A, or 737 for B system)
Programming control channels to scan:
NAM4 only
Use the arrow key to scroll to the #DCCS (number of dedicated control
channels) display. Enter the total number of control channels that the DCSM
is assigned to scan (1 to 21 channels).
For NAM4 only:
Use the arrow key to scroll to 1STCHA1 display. Enter the A side primary
control channel (IS-54B and IS-136.2 default 333).
Summary of Contents for DualMode 800
Page 2: ......
Page 4: ......
Page 6: ...vi Publication history Nortel Networks Confidential 411 2051 500 Draft 00 01 November 1999...
Page 82: ...2 20 Periodic maintenance 411 2051 500 Draft 00 01 November 1999...
Page 90: ...3 8 Test equipment and precautions 411 2051 500 Draft 00 01 November 1999...
Page 100: ...5 6 Master Oscillator tests 411 2051 500 Draft 00 01 November 1999...
Page 106: ...6 6 Antenna and transmission line tests 411 2051 500 Draft 00 01 November 1999...
Page 116: ...8 4 Alarm Control Unit ACU tests 411 2051 500 Draft 00 01 November 1999...
Page 138: ...10 2 ICRM tests 411 2051 500 Draft 00 01 November 1999...
Page 200: ...12 10 Enclosure maintenance 411 2051 500 Draft 00 01 November 1999...
Page 208: ...A 8 Appendix A Frequency table 411 2051 500 Draft 00 01 November 1999...
Page 215: ......