DRU receive tests
11-23
Wireless Solutions
DualMode 800 Enclosure
Maintenance Manual
MTX08
The DRU will request a channel number. Enter the channel number for the
frequency assigned to the DRU under test (1...799 or 990...1023). Refer to
Appendix A for the channel-to-frequency conversion information.
>xxxx
On a successful channel change, the Channel and Synth Lock fields will
be updated:
Channel: xxxx
(DRU channel number indicated)
Synth Lock: YES
(Sync Lock changes to ‘YES’)
5. On the communications monitor, set the receiver RF frequency to the
frequency corresponding to that of the DRU under test. For an IFR 1600,
by selecting the transmitter frequency, the receiver frequency will
automatically be set.
6. Proceed with the receive tests.
After performing a receive test on the A path of the receiver, perform the test
again on the B path. From the terminal, use the N command to change the
Antenna Path to ‘B’ and use the M command to select antenna port 4 for the
new receive path.
Note: Change the connection to the antenna input port 4 accordingly.
For sectored sites, perform also the following:
1. Use the N command to change the Antenna Path to ‘A’ and use the M
command to change the antenna ports to 2 and 5. Perform the receive
tests.
2. Use the N command to change the Antenna Path to ‘B’ and ensure that the
antenna ports are still 2 and 5. Perform the receive tests.
3. Use the N command to change the Antenna Path to ‘A’ and use the M
command to change the antenna ports to 3 and 6. Perform the receive
tests.
4. Use the N command to change the Antenna Path to ‘B’ and ensure that the
antenna ports are still 3 and 6. Perform the receive tests.
Note: Change the connection to the antenna input ports accordingly.
Summary of Contents for DualMode 800
Page 2: ......
Page 4: ......
Page 6: ...vi Publication history Nortel Networks Confidential 411 2051 500 Draft 00 01 November 1999...
Page 82: ...2 20 Periodic maintenance 411 2051 500 Draft 00 01 November 1999...
Page 90: ...3 8 Test equipment and precautions 411 2051 500 Draft 00 01 November 1999...
Page 100: ...5 6 Master Oscillator tests 411 2051 500 Draft 00 01 November 1999...
Page 106: ...6 6 Antenna and transmission line tests 411 2051 500 Draft 00 01 November 1999...
Page 116: ...8 4 Alarm Control Unit ACU tests 411 2051 500 Draft 00 01 November 1999...
Page 138: ...10 2 ICRM tests 411 2051 500 Draft 00 01 November 1999...
Page 200: ...12 10 Enclosure maintenance 411 2051 500 Draft 00 01 November 1999...
Page 208: ...A 8 Appendix A Frequency table 411 2051 500 Draft 00 01 November 1999...
Page 215: ......