170
Chapter 25
Speech Intelligibility by STIPA
Using Excel for further calculations
An Excel workbook “STIPA-Calc” is delivered with the
STIPA-option. The workbook allows you to correct your
readings for different speech levels and levels of back-
ground noise similar to the corrections available in the
instrument.
Recall the stored results from an earlier measure-
ment. Press the button
TBL
to display the speech level
and enter the levels into the cells for the speech level.
Press
TBL
once more to obtain the modulation indices
and bring the values into the appropriate cells. You
may then enter values for the background noise and
see how this will affect your reading.
The values from the STIPA-measurement may be
transferred to the PC by using the USB or serial inter-
face on the instrument. A transfer program like NorXfer
may be used.
STI-Calc
In the zipped file with STIPA-calc, you will also find a
program called STI calc. This program may be used
to estimate the STI-value based on information on the
octave-band levels for speech and background noise
and the reverberation of the room – also in octave
bands. The applied formulas assume linearity and that
the impulse response for the room is well behaved
without significant echoes. The calculation should not
be used as a replacement for a real measurement of
the STI-value.
Specifications
The STI-value is measured according to the require-
ments for STIPA method defined in:
IEC 60268-16 (Ed.4.0 2011-06): Sound system equip-
ment – Part 16: Objective rating of speech intelligibility
by speech transmission index.
The CIS-value is calculated from the STI-value as
specified in:
IEC 60849 (Ed. 2.0 1998-02) Sound systems for emer-
gency purposes.
Summary of Contents for nor140
Page 4: ......
Page 16: ......
Page 17: ...nor140 SOUND ANALYSER ...
Page 18: ......
Page 212: ...194 ...
Page 218: ......