202
BATTERY
10e
Inspection and adjustment
10f-2.
<Checking electrolyte level>
1. Disconnect the battery plug.
2. Open the battery cover and set the stopper.
3. Check electrolyte level.
Inspection of quantity of electrolyte
and replenishment
4
1
10f-2-1. Battery - inspection
CAUTION
Since a gas spring (an assistant damper with
self-lock function) is used, the locking state
should be checked.
<Specification>
l
If the red float can seen, electrolyte level is normal.
If not, add refined or distilled water to the approproate
level.
<Adding refined water>
1. Open the cap of the battery cell.
2. Add the distilled or refined water until the top of the
red float is touched to the plate of the cap.
CAUTION
Do not add any sulfuric acid in the battery cell.
The elec t roly te is the dilute sulfuric acid,
however, only distilled or refind water can be
used to add.
NOTE
The illustration shows the Japanese standard
battery and the actual battery on the truck may
have the different structure.
Refer the instruction from the battery supplier
for details.
Battery
White line
Level of
electrolyte
Float
Cap
Proper level of electrolyte
Lowest level of electrolyte
Add refined water to
the appropriate level.
Appropriate level
l
Inspection of electrolyte level
l
Adding water