148
MOTOR
9
l
Traction motor
1) Connect the U1 cable from the chassis to the U1 terminal on the motor.
2) Connect the V1 cable from the chassis to the V1 terminal on the motor.
3) Connect the W1 cable from the chassis to the W1 terminal on the motor.
4) Connect the wire harness from the chassis
(water resistant type 4P) to the connector of the speed sensor in the motor
(water resistant type 4P).
l
Hydraulic motor
1) Connect the U2 cable from the chassis to the U2 terminal on the motor.
2) Connect the V2 cable from the chassis to the V2 terminal on the motor.
3) Connect the W2 cable from the chassis to the W2 terminal on the motor.
l
Inspect the the motor with following procedures.
l
Operate the motor. Make sure there is no abnormal
noise.
<
Checking procedure
>
1. Be sure to secure the motor ASS'Y on a work bench.
2. Use the battery of the forklift truck to carry out testing.
3. Connect wires as follows.
Abnormal noise check
4
1
If an extension cable is necessary, make them with the following parts:
1) Main cables for motor (3 cables)
1. Cable size : 38 mm
2
2. Terminal : 38-S8
2) Lead wires for speed sensor (4 wires)
1. Wire size : 0.5 mm
2
2. Receptacle : AMP171662-1
3. Tab : AMP173600-1
4. "Housing, cap 4P" : 37010-20940(AMP174259-2)
5. "Housing, plug 4P" : 37010-20890(AMP174257-2)
CAUTION
If the motor is tested by itself, fix the motor on
a work bench securely. The motor may move
suddenly when starting.
Test the motor with the slow speed.
CAUTION
9-3-4. Motor ASS'Y (Traction/Hydraulic motor) - inspection
https://www.forkliftpdfmanuals.com/