174
MAIN CONTACTOR AND FUSE
10d
10A,
Glass tube fuses
(F4, F6)
160A,
charger fuse
40A, EPS fuse (F3)
325A,
travel/Hydraulic fuse
(F1)
221W064E
Inspection and replacement
10d-2.
2. Use the tightening torque shown on the right for the
main terminal area (M8).
1. Remove screws, and check for burns or wear in the
contact area.
If there is an abnormality in the contact, replace the
assembly.
M8
121W226
l
Main terminal area (M8)
l
Inspection of main contactor
: Tightening torque
1. Be sure to replace Fuse with the specific capacity one.
2. Be sure to tighten the nuts after replacing it.
l
Fuse type
l
Main contactor type
l
Fuse type
CAUTION
l
Record places of lead wire connections before
disassembling.
l
Be sure to disconnect the battery plug.
CAUTION
To be safe, the assembly should be replaced
every 2 years even if there are no abnormalities.
10d-2-1. Main contactor - inspection and replacement
10d-2-2. Fuse - replacement
Tightening torque (M8)
6.4-7.4 N
m
{0.65-0.75 kgf
m}
Applicable model
Maker type
Voltage
FB10P-30P
HR-404394
48V
Application
Capacity
MPU
F1
325A
EPS
F3
40A
Transformer
160A
Control unit
F4
10A
Accessory
F6
10A
https://www.forkliftpdfmanuals.com/