background image

www.ravas.com

iJack - 40

iJack - 40  

(4,000 LBS. Capacity)

(4,000 LBS. Capacity)

Owner’s Manual

www.ravas.com

Summary of Contents for iJack-40

Page 1: ...www ravas com iJack 40 iJack 40 4 000 LBS Capacity 4 000 LBS Capacity Owner s Manual www ravas com...

Page 2: ...equest The manufacturer accepts no liability for any damage or injury caused by failure to follow these instructions or from negligent operation or assembly even if this is not expressly stated in thi...

Page 3: ...let Truck 5 320 Indicator 6 Indicator Functions 7 Indicator Calibration 8 Touch Panel Indicator 9 Printer Opton 10 Relay Option 11 Trouble Shooting 12 Parameter Settings 4 5 7 8 10 11 13 19 21 22 26 3...

Page 4: ...neration Drive Technology and Brushless DC Motor There is No Need to Replace the Carbon Brush and the Drive is More Powerful The iJack 40 s Maximum Gradeability Can Reach 10 with the Load of 3 000 lbs...

Page 5: ...Travel Speed with without Load Lifting Speed with without Load Lowering Speed with without Load Max Gradeability with without Load Service Brake Drive Motor Rating 60 Min Lift Motor Rating at 15 Batt...

Page 6: ...www ravas com 6 iJack 40...

Page 7: ...ees in the proper use and maintenance of this equipment 7 Do not operate this unit unless you have been fully trained of its capabilities 8 Do not use the weighing system in potentially explosive area...

Page 8: ...be centered over the forks of the pallet truck and be able to lift freely without touching the electric pallet truck or other pallets The wheels of the electric pallet truck must not be touching the p...

Page 9: ...n to prevent damage to the load cells Main guidelines Clean only with a damp cloth Chemical cleaners and high pressure washers will cause damage to the system System should be cleaned regularly to rem...

Page 10: ...n Three data output modes print continuous and command answer lb or kg toggle Internal clock for recording date time on printout Error messages in display Power supply to printer switched on and off b...

Page 11: ...ght is in pounds low bat indicator ZERO NET e1 e2 e3 the weighing system including load is stable the weight shown is negative the weight shown is within the zero range the display is showing the net...

Page 12: ...ive On switch And change to lb and kg code entry pre set tare check subtotal and print reset total no function Off switch enter decrease the value of the digit flashing increase the value of the digit...

Page 13: ...t Tare Gross weight EXPLANATION Net 1 Tare 2 Gross 3 1 2 3 e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR The...

Page 14: ...KG LB CLR e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR The display shows the net value of the weighed load The gross weight is displayed again NOTE for OIML approved RAVAS 320 the tare will be erase...

Page 15: ...G LB CLR e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR e1 e2 e3 F1 F2 NET ID CODE PT TOTAL KG LB CLR Press ENTER to activate the tare weight Press the T k...

Page 16: ...PT TOTAL KG LB CLR When the pallet wagen is completely unloaded the tare value is displayed negatively The NET pointer lights up NOTE for OIML approved RAVAS 320 the tare will be erased automat icall...

Page 17: ...nter is installed a printout will be made The gross net and tare weights are printed Press the TOTAL key to add the weight load to the total weight If a printer is installed a printout will be made Th...

Page 18: ...R 3 sec 3 sec CLR TOTAL KG LB CLR RESET TOTAL PRINT RESET TOTAL The subtotal can be checked by pressing the TOTAL key for 3 sec 3X NOTE In case the total is not manually used or reset the system will...

Page 19: ...splay in order to show low battery status THE DISPLAY By means of eight pointer bars the display shows the weighing system including load is stable the weight shown is negative ZERO the weight shown i...

Page 20: ...increase the value of the digit flashing sampling a piece weight enter a piece weight shift to the next digit on the left on off switch toggle units clear entry IMPORTANT Operation of a key is not acc...

Page 21: ...ers PT The total weight is shown with the letters TOT Standard printout without code Standard printout with code B G 1234 5 kg CODE 12345 T 34 5 kg B G 1234 5 kg N 1200 0 kg T 34 5 kg N 1200 0 kg Nr 1...

Page 22: ...ccept or change the date of the month setting The display will show m_00 or the previous month setting with the right digit flashing Repeat the above procedure to accept or change the month setting Th...

Page 23: ...the display returns to the weighing mode DOSING FILLING with Manual Tare Start In this setting set point 1 and 2 are switched on as soon as the tare key has been activated and after the set point valu...

Page 24: ...stp2 will turn off and relay 2 will be opened The display shows done for a few seconds and returns in the normal weighing mode The net weight is displayed A printout may be made at this point It is p...

Page 25: ...ds and will return in the normal weighing mode The net weight is displayed A printout may be made at this point It is possible to cancel the filling or dosing procedure at any time by pressing the CE...

Page 26: ...gger difference then 5 lb you have a load cell or a mechanical problem To make sure it is a mechanical problem repeat test with a heavy load on the scale Lift a pallet with 2000 or 3000 lb Reset Indic...

Page 27: ...k cable Very rarely the cause Maybe in a lift truck Instability With no load it is most of the time humidity bad connection or component r bad shield Check for humidity Check for water marks on the in...

Page 28: ...el Test can be done by making short cut on connection of the touch panel to simulate a key being pressed Check for wear of broken contacts in the flat cable going to the indicator board Lock up Take o...

Page 29: ...ion after this action a complete new calibration and stamping of the system is necessary Automatic Automatic Lift up the forks from the ground Put the pallet truck into horizontal position Charge the...

Page 30: ...ting for this parameter at this moment You may change the setting by using the or the key OR You can accept the setting by pressing OR OR To move to the next parameter you press the key To move to the...

Page 31: ...sitive 0 100 approved 2 of span 10 10 Zero range negative 0 100 approved 2 of span 10 11 Test Function ADC Counts bASIC BASIC 10x Resolution 12 Power On zero Yes No No 13 Approved None NTEP OIML NTEPC...

Page 32: ...RLF cr 25 Dataprotocol comport 1 0 PC bi directional 1 PC Excel format on print command 2 remote display 3 printer with power control 4 printer without power control 5 not used 6 PC excel format on pr...

Page 33: ...10 0 not used 1 0 44 Comp factor rdx 0 1 to 10 0 not used 1 0 45 Comp factor rdy 0 1 to 10 0 not used 1 0 46 T comp factor zero not used 1 0 47 Not used 48 T comp factor span not used 0 49 Underload...

Page 34: ...s will have the EU settings 91 Reset to default parameter settings including calibration parameters If parameter 01 was on 1 it will default to the EU settings if P01 2 the US settings will be default...

Reviews: