39
04 - Control System
Code
Description
Comments
2-041
M1 Overcurrent
The power module has detected that the amperage to the associated motor
is beyond the limits of the power module. Possible causes for this could be
short circuit or locked motor rotor.
2-042
M2 Overcurrent
2-043
M3 Overcurrent
2-044
M4 Overcurrent
2-045
M5 Overcurrent
2-046
M6 Overcurrent
2-047
M7 Overcurrent
2-048
M10 Overcurrent
2-051
M1 Mosfet Short
The power module has detected that the output switching transistor for
the respective motor is not switching off when expected. If the condition
persists, the likely cause is that the power module has failed and needs
replacement.
2-052
M2 Mosfet Short
2-053
M3 Mosfet Short
2-054
M4 Mosfet Short
2-055
M5 Mosfet Short
2-056
M6 Mosfet Short
2-057
M7 Mosfet Short
2-058
M10 Mosfet Short
2-061
M1 Current Sensor
The power module has detected unexpected results for the applicable
output current sensor. If the motor appears to be operating correctly, the
power module may be damaged.
2-062
M2 Current Sensor
2-063
M3 Current Sensor
2-064
M4 Current Sensor
2-065
M5 Current Sensor
2-066
OverTemp Cutoff
Internal temperature exceeds Cutoff Temperature
2-067
UnderTemp Cutoff
Internal temperature below -40°
2-071
M1 Overload Trip
An existing overload condition has continued for a preset time period and
the power module has shut down the load.
2-072
M2 Overload Trip
2-073
M3 Overload Trip
2-074
M4 Overload Trip
2-075
M5 Overload Trip
2-076
M6 Stall
The motor current has exceeded the stall value. The motor will not be
operated in the stalled direction until it is first operated in the opposite
direction.
2-077
M7 Stall
2-078
M10 Stall
2-081
EEPROM Fault
EEPROM checksum error
2-082
PDO Timeout
Time between PDO messages exceeded PDO timeout.
2-083
CAN Bus
Internal CAN Bus counter exceeded 128
2-084
Actuator Timeout
Internal master does not receive the slave message in the timeout period.
2-086
OverTemp Cutback
Internal temperature exceeded the cutback temperature. The output current
limits will be reduced.
2-087
UnderTemp Cutback
The internal temperature is below -25°C. Output power will be reduced to
50%.
2-088
K2 Coil Open
The module has detected an open circuit at the K2 relay coil.