43
04 - Control System
Power Module Heavy Current Lugs
Measured
Value/Condition
B+ lug to B- lug
36.5V (with Vacuum motor on 100%)
B+ lug to Battery Positive
0.031V (with Vacuum motor on 100%)
B- lug to Battery Negative
0.017V (with Vacuum motor on 100%)
M1 to Battery Negative
36.9V off
0.019 on at 100%
M2 to Battery Negative
36.9V off
0.018 on at 100%
M3 to Battery Negative
36.9V off
9.5V on at 76%
M4 to Battery Negative
36.7V off
0.081 on at 100%
M5 to Battery Negative
Not present, assume same as M4
Motor Amp Draw measurements
All motor amp draw measurements were done with no load (free running) using the Service/Output Test
function and reading the amperage reported on the control panel display
Motor
Amperage (On Display)
M1 Brush Motor (Cylindrical)
4.0A at 100%
M1 Brush Motor (Disc)
2.6-3.0A at 100%
M2 Brush Motor (Cylindrical)
4.0A at 100%
M2 Brush Motor (Disc)
2.6-3.0A at 100%
M3 Side Broom Motor
1.6A at 76%
M4 Vacuum Motor
18.1A at 100%
M5 Vacuum Motor (Optional)
Not measured
M6 Squeegee Actuator Motor
Up: 4.1A initial, then 2.6A
Down: 0.9-1.2A
M7 Deck Actuator Motor
Up: 4.1A initial, then 2.6A
Down: 0.9-1.2A
M10 Dust Guard Pump Motor
0.4-0.7A