86
30 - Solution System
Operational Mode Prerequisites
Before the main controller can activate any of the operational modes, it must first check that the appropriate
prerequisites are met
•
Solution System Outputs
– Solution Solenoid L1 –
◦
Scrub system active
◦
No solution solenoid fault
◦
No recovery system fault (vac motors and squeegee)
◦
Throttle command not equal to zero
◦
No Estop inhibit
◦
No impact lockout inhibit
◦ No low voltage cut out inhibit (first or second stage)
◦
No RTF inhibit
◦
Not turned off with the membrane switch
◦
Not momentarily turned off by the solution timed off paddle switch input
– Spray wash pump M10
◦
No spray wash pump M10 fault
◦
Solution tank is not empty
◦ Option (Opt) pump in configuration menu set to “Spray Wash”
•
Detergent System outputs
– Detergent Pumps M8 and M9
◦
Solution system is active
◦ EcoFlex is enabled in the configuration menu
◦
Not turned off with the control panel detergent switch