104
34 - Scrub System, Cylindrical
The down-limit cam isn’t adjustable, but by adjusting the position of the up-limit cam, the actuator can
control its length of travel for the leadnut along the leadscrew
M
CW
CCW
Scrub Control
Scrub pressure is controlled by monitoring the motor amperage from both brush motors If the combined
brush motor current is below its target amperage, the deck is lowered slightly to increase brush pressure If
the combined amperage is above the target amperage, the deck is raised slightly Additionally, if either one
of the motors is operating above its maximum allowed amperage, the deck is raised
The motor amperage is sampled every 250ms, but adjustments are made only at 45 second intervals to filter
out minor variations in the floor. The instantaneous amperage readings are averaged for the 45 second
interval
Deck Type
Floor Type
Scrub Level
Min Amps
Max Amps
34D
860D
Standard
Low
20
30
High
30
40
Extreme
40
50
Smooth
Low
15
25
High
25
35
Extreme
35
45
Individual Motor Max
25
40D
1050D
Standard
Low
20
30
High
30
40
Extreme
40
50
Smooth
Low
15
25
High
25
35
Extreme
35
45
Individual Motor Max
25
36C
910C
Standard
Low
20
30
High
30
40
Extreme
40
50
Smooth
Low
15
25
High
25
35
Extreme
35
45
Individual Motor Max
25