WF1947/WF1948 Instruction Manual (External Control)
iv
2.3.4
Output Signal Setting Command Details ............................................................................................ 61
2.3.4.1
Frequency setting/query [:SOURce[1|2]]:FREQuency[:CW|:FIXed] ........................................ 61
2.3.4.2
Frequency unit selection/query [:SOURce[1|2]]:FREQuency:UNIT ......................................... 61
2.3.4.3
Frequency user-defined unit setting/query [:SOURce[1|2]]:FREQuency:USER ....................... 62
2.3.4.4
Amplitude setting/query [:SOURce[1|2]]:VOLTage[:LEVel][:IMMediate][:AMPLitude] ...... 63
2.3.4.5
Amplitude unit selection/query
[:SOURce[1|2]]:VOLTage[:LEVel][:IMMediate][:AMPLitude]:UNIT ................................. 63
2.3.4.6
Amplitude user-defined unit setting/query
[:SOURce[1|2]]:VOLTage[:LEVel][:IMMediate][:AMPLitude]:USER ................................. 64
2.3.4.7
DC offset setting/query [:SOURce[1|2]]:VOLTage[:LEVel][:IMMediate]:OFFSet ................. 65
2.3.4.8
DC offset unit setting/query [:SOURce[1|2]]:VOLTage[:LEVel][:IMMediate]:OFFSet:UNIT65
2.3.4.9
DC offset user-defined unit setting/query
[:SOURce[1|2]]:VOLTage[:LEVel][:IMMediate]:OFFSet:USER .......................................... 66
2.3.4.10
Phase setting/query [:SOURce[1|2]]:PHASe[:ADJust] ............................................................... 67
2.3.4.11
Phase unit selection/query [:SOURce[1|2]]:PHASe:UNIT ......................................................... 67
2.3.4.12
Phase user-defined unit setting/query [:SOURce[1|2]]:PHASe:USER....................................... 68
2.3.4.13
Output voltage range high level setting/query
[:SOURce[1|2]]:VOLTage[:LEVel][:IMMediate]:HIGH ......................................................... 69
2.3.4.14
Output voltage range high level unit selection/query
[:SOURce[1|2]]:VOLTage[:LEVel][:IMMediate]:HIGH:UNIT .............................................. 69
2.3.4.15
Output voltage range low level setting/query
[:SOURce[1|2]]:VOLTage[:LEVel][:IMMediate]:LOW .......................................................... 70
2.3.4.16
Output voltage range low level unit selection/query
[:SOURce[1|2]]:VOLTage[:LEVel][:IMMediate]:LOW:UNIT .............................................. 70
2.3.5
Signal Output Operation Command Details .......................................................................................... 71
2.3.5.1
Output on/off setting/query :OUTPut[1|2][:STATe] ................................................................... 71
2.3.5.2
Output-on at power-on setting/query :OUTPut[1|2]:PON ........................................................... 71
2.3.5.3
Auto-range operation (output range) selection/query
[:SOURce[1|2]]:VOLTage:RANGe:AUTO .............................................................................. 72
2.3.5.4
Phase synchronization setting [:SOURce[1|2]]:PHASe:INITiate ............................................... 72
2.3.5.5
External addition input setting/query [:SOURce[1|2]]:COMBine:FEED ................................... 72
2.3.5.6
Load impedance setting/query :OUTPut[1|2]:LOAD .................................................................. 73
2.3.6
Trigger Operation Command Details .................................................................................................... 74
2.3.6.1
Trigger operation Manual trigger (TRIG key operation) *TRG ................................................. 74
2.3.6.2
Trigger operation sweep mode trigger source
selection/query :TRIGger[1|2]:SWEep:SOURce ...................................................................... 74
2.3.6.3
Trigger operation sweep mode internal trigger cycle
setting/query :TRIGger[1|2]:SWEep:TIMer .............................................................................. 75
2.3.6.4
Trigger operation sweep mode external trigger signal polarity
selection/query :TRIGger[1|2]:SWEep:SLOPe ......................................................................... 75
2.3.6.5
Trigger operation burst mode trigger source selection/query :TRIGger[1|2]:BURSt:SOURce 76
2.3.6.6
Trigger operation burst mode internal trigger cycle
Summary of Contents for Wave Factory WF1947
Page 1: ...MULTIFUNCTION GENERATOR Instruction Manual External Control WF1947 WF1948 NF Corporation ...
Page 2: ......
Page 3: ...DA00037649 002 MULTIFUNCTION GENERATOR Instruction Manual External Control WF1947 WF1948 ...
Page 4: ......
Page 20: ...WF1947 WF1948 Instruction Manual External Control xvi ...
Page 21: ...WF1947 WF1948 Instruction Manual External Control 1 1 Preparations before Use ...
Page 28: ...8 WF1947 WF1948 Instruction Manual External Control 8 ...
Page 29: ...9 WF1947 WF1948 Instruction Manual External Control 9 2 Command Descriptions ...
Page 179: ...WF1947 WF1948 Instruction Manual External Control 159 3 Status System ...
Page 189: ...WF1947 WF1948 Instruction Manual External Control 169 ...
Page 196: ...WF1947 WF1948 Instruction Manual External Control 176 4 Error Message ...
Page 199: ...WF1947 WF1948 Instruction Manual External Control 179 ...
Page 200: ...WF1947 WF1948 Instruction Manual External Control 180 5 Specifications ...
Page 202: ...WF1947 WF1948 Instruction Manual External Control 182 5 3 Multi Line Interface Message ...
Page 203: ...WF1947 WF1948 Instruction Manual External Control 183 ...
Page 204: ...WF1947 WF1948 Instruction Manual External Control 184 6 Compatibility of External Control ...
Page 315: ......