WF1947/WF1948 Instruction Manual (External Control)
283
6.3.150 UOU/?UOU
Description
Sets/queries the user-defined unit of DC offset.
Parameters
The last three parameter among four can be omitted.
The unit name
Type 1: Up to character string data of 4 characters
Type 2 (For reference): Up to character string data of 4 characters
or DEFault (handled same as "USER").
Use/not use of LOG
Type 1 Type 2 (For reference)
0: NONE (LOG is not used. The user setting = (original value + offset) x scale)
1 : LOGarithmic
(LOG is used. The user setting = (log (original value) + offset) x scale)
Scale
The scaling factor: -9.9 to +9.9 (except for 0)
The exponent of the scaling factor is E-9 to E+9.
Offset
Scaling factor: -9.4 to +9.4
The exponent of the scaling factor is E-4 to E+4.
Response format
Unit name, 0/1, scale, offset
Type 2 (For reference)
Settings: [:SOURce]:VOLTage[:LEVel][:IMMediate]:OFFSet:USER
{<unit name>|DEFault}[,{NONE|LOGarithmic|DEFault}
[,{<scale>|DEFault}[,{<offset>|DEFault}]]]
Query: [:SOURce]:VOLTage[:LEVel][:IMMediate]:OFFSet:USER?
Setting example
The name of the DC offset unit is "kgf". LOG is not used. The scale is 9.8. The offset is
set to 0.
Type 1: UOU “kgf”,0,9.8,0
Type 2 (For reference):VOLT:OFFS:USER “kgf”,NONE,9.8,0
Note
When LOG is used, negative values cannot be set as the phase.
Compatibility Information
Compatibility support
Summary of Contents for Wave Factory WF1947
Page 1: ...MULTIFUNCTION GENERATOR Instruction Manual External Control WF1947 WF1948 NF Corporation ...
Page 2: ......
Page 3: ...DA00037649 002 MULTIFUNCTION GENERATOR Instruction Manual External Control WF1947 WF1948 ...
Page 4: ......
Page 20: ...WF1947 WF1948 Instruction Manual External Control xvi ...
Page 21: ...WF1947 WF1948 Instruction Manual External Control 1 1 Preparations before Use ...
Page 28: ...8 WF1947 WF1948 Instruction Manual External Control 8 ...
Page 29: ...9 WF1947 WF1948 Instruction Manual External Control 9 2 Command Descriptions ...
Page 179: ...WF1947 WF1948 Instruction Manual External Control 159 3 Status System ...
Page 189: ...WF1947 WF1948 Instruction Manual External Control 169 ...
Page 196: ...WF1947 WF1948 Instruction Manual External Control 176 4 Error Message ...
Page 199: ...WF1947 WF1948 Instruction Manual External Control 179 ...
Page 200: ...WF1947 WF1948 Instruction Manual External Control 180 5 Specifications ...
Page 202: ...WF1947 WF1948 Instruction Manual External Control 182 5 3 Multi Line Interface Message ...
Page 203: ...WF1947 WF1948 Instruction Manual External Control 183 ...
Page 204: ...WF1947 WF1948 Instruction Manual External Control 184 6 Compatibility of External Control ...
Page 315: ......