WF1947/WF1948 Instruction Manual (External Control)
232
6.3.58 HIV/?HIV
Description
Sets/queries the setting of the high level. This setting is ignored during the
amplitude/offset sweep.
In a query for the amplitude/offset sweep and the modulation, an instantaneous value is
returned at that time.
When LOG is used with the high level user-defined unit of the "UHU" command,
specify as follows.
When the actual high level is 0, the response is “-INF” or “+INF”. To specify the value,
specify “-INF”/“+INF”.
When the actual high level is negative, the response is “OVER”. You cannot specify the
actual high level as negative.
Parameters
High level setting (the range changes based on the unit and the LOAD settings)
When the range is 10V ,the load is open, and the unit is V: -10 (-10V) to + 10 (10V)
When the user-defined unit is selected, the setting/query cannot be less than 0V.
Type 2 (For reference)
Settings: [:SOURce]:VOLTage[:LEVel][:IMMediate]:HIGH
{<high>|MINimum|MAXimum}
Query: [:SOURce]:VOLTage[:LEVel][:IMMediate]:HIGH? [MINimum|MAXimum]
Setting example
Sets the high level to +5V. It is assumed that the high level unit is selected as V, and
LOAD is set to OPEN in advance.
Type 1: HIV 5
Type 2 (For reference):VOLT:HIGH 5
Compatibility Information
Compatibility support
The maximum value is changed, compared to the old WF194x.(20V
10V)
Summary of Contents for Wave Factory WF1947
Page 1: ...MULTIFUNCTION GENERATOR Instruction Manual External Control WF1947 WF1948 NF Corporation ...
Page 2: ......
Page 3: ...DA00037649 002 MULTIFUNCTION GENERATOR Instruction Manual External Control WF1947 WF1948 ...
Page 4: ......
Page 20: ...WF1947 WF1948 Instruction Manual External Control xvi ...
Page 21: ...WF1947 WF1948 Instruction Manual External Control 1 1 Preparations before Use ...
Page 28: ...8 WF1947 WF1948 Instruction Manual External Control 8 ...
Page 29: ...9 WF1947 WF1948 Instruction Manual External Control 9 2 Command Descriptions ...
Page 179: ...WF1947 WF1948 Instruction Manual External Control 159 3 Status System ...
Page 189: ...WF1947 WF1948 Instruction Manual External Control 169 ...
Page 196: ...WF1947 WF1948 Instruction Manual External Control 176 4 Error Message ...
Page 199: ...WF1947 WF1948 Instruction Manual External Control 179 ...
Page 200: ...WF1947 WF1948 Instruction Manual External Control 180 5 Specifications ...
Page 202: ...WF1947 WF1948 Instruction Manual External Control 182 5 3 Multi Line Interface Message ...
Page 203: ...WF1947 WF1948 Instruction Manual External Control 183 ...
Page 204: ...WF1947 WF1948 Instruction Manual External Control 184 6 Compatibility of External Control ...
Page 315: ......