Manage Device Security
310
Insight Managed 28-Port Gigabit Ethernet Smart Cloud Switch with 2 SFP 1G & 2 SFP+ 10G Fiber Ports
16.
From the
EtherType Key
menu, select the EtherType value that must be compared against
the information in an Ethernet frame.
The valid values are as follows:
•
Appletalk
•
ARP
•
IBM SNA
•
IPv4
•
IPv6
•
IPX
•
MPLS multicast
•
MPLS unicast
•
NetBios
•
Novell
•
PPPoE
•
RARP
•
User Value
17.
If you select
User Value
from the
EtherType
menu, in the
EtherType User Value
field,
specify the customized EtherType value that must be used when you select
User Value
from the
EtherType Key
menu.
This value must be compared against the information in an Ethernet frame. The valid range
of values is 0x0600 to 0xFFFF.
18.
In the
Source MAC
field, specify the source MAC address that must be compared against
the information in an Ethernet frame.
The valid format is xx:xx:xx:xx:xx:xx.
19.
In the
Source MAC Mask
field, specify the source MAC address mask that must be
compared against the information in an Ethernet frame.
The valid format is xx:xx:xx:xx:xx:xx.
The MAC mask specifies which bits in the MAC address must be compared against an
Ethernet frame. You can use Fs and zeros in the MAC mask, which is in a wildcard
format. An F means that the bit is not checked, and a zero in a bit position means that the
data must equal the value given for that bit. For example, if the MAC address is
aa:bb:cc:dd:ee:ff, and the mask is 00:00:ff:ff:ff:ff, all MAC addresses with
aa:bb:xx:xx:xx:xx result in a match (where x is any hexadecimal number). A MAC mask of
00:00:00:00:00:00 matches a single MAC address.
20.
In the
VLAN
field, specify the VLAN ID that must be compared against the information in an
Ethernet frame.
The valid range of values is 1 to 4093. Either VLAN range or VLAN can be configured.
21.
From the
Logging
menu, select whether to enable or disable logging.