Configure Switching
129
Insight Managed 28-Port Gigabit Ethernet Smart Cloud Switch with 2 SFP 1G & 2 SFP+ 10G Fiber Ports
VoIP frames that are received on ports that for which the Auto-VoIP feature is enabled are
marked with the specified CoS traffic class value.
To configure protocol-based port settings:
1.
Connect your computer to the same network as the switch.
You can use a WiFi or wired connection to connect your computer to the network, or
connect directly to a switch that is off-network using an Ethernet cable.
2.
Launch a web browser.
3.
In the address field of your web browser, enter the IP address of the switch.
If you do not know the IP address of the switch, see
The login window opens.
4.
Enter the switch’s password in the
password
field.
The default password is
password
. If you added the switch to a network on the Insight
app before and you did not yet change the password through the local browser interface,
enter your Insight network password.
The System Information page displays.
5.
Select
Switching > Auto-VoIP > Protocol-based > Port Settings
.
The page displays the Protocol Based Global Settings section and the Protocol Based
Port Settings section.
6.
From the
Prioritization Type
menu, select
Traffic Class
or
Remark
.
This specifies the type of prioritization.
7.
From the
Class Value
menu, specify the CoS tag value to be reassigned for packets
received on the voice VLAN when Remark CoS is enabled.
8.
To display information for all ports and LAGs, click the
All
link.
9.
Select one or more interfaces by taking one of the following actions:
•
To configure a single interface, select the check box associated with the port, or type
the port number in the
Go To Interface
field and click the
Go
button.
•
To configure multiple interfaces with the same settings, select the check box
associated with each interface.
•
To configure all interfaces with the same settings, select the check box in the heading
row.
10.
From the
Auto VoIP Mode
menu, select
Disable
or
Enable
.
Auto-VoIP is disabled by default.
The
Operational Status
field displays the current operational status of each interface.
11.
Click the
Apply
button.