"nodes": [
{
"bmcDetails": {
"bmcAddress": "10.111.0.111",
"credentialsAvailable": true,
"credentialsValidated": true
},
"chassisSerialNumber": "111930011231",
"chassisSlot": "D",
"hardwareId": "123a4567-01b1-1243-a12b-11ab11ab0a15",
"hardwareTag": "00000000-0000-0000-0000-ab1c2de34f5g",
"id": "e1111d10-1a1a-12d7-1a23-ab1cde23456f",
"model": "H410C",
3. Run the compute node firmware upgrade:
a. Open the hardware service REST API UI on the management node:
https://[management node IP]/hardware/2/
b. Click
Authorize
and complete the following:
i. Enter the cluster user name and password.
ii. Enter the client ID as
mnode-client
.
iii. Click
Authorize
to begin a session.
iv. Close the authorization window.
c. Click
POST /nodes/{hardware_id}/upgrades
.
d. Click
Try it out
.
e. Enter the hardware host asset ID (
"hardwareId"
saved from a previous step) in the parameter field.
f. Do the following with the payload values:
i. Retain the values
"force": false
and
"maintenanceMode": true"
so that health checks
are performed on the node and the ESXi host is set to maintenance mode.
ii. Enter the cluster controller ID (
"controllerId"
saved from a previous step).
iii. Enter the package name and package version you saved from a previous step.
Summary of Contents for HCI