![NetApp HCI Manual Download Page 164](http://html1.mh-extra.com/html/netapp/hci/hci_manual_1669957164.webp)
"nodes": [
{
"bmcDetails": {
"bmcAddress": "10.117.1.111",
"credentialsAvailable": false,
"credentialsValidated": false
},
"chassisSerialNumber": "221111019323",
"chassisSlot": "C",
"hardwareId": null,
"hardwareTag": "00000000-0000-0000-0000-ac1f6ab4ecf6",
"id": "8cd91e3c-1b1e-1111-b00a-4c9c4900b000",
2. Open the hardware service REST API UI on the management node:
https://[management node IP]/hardware/2/
3. Click
Authorize
and complete the following:
a. Enter the cluster user name and password.
b. Enter the client ID as
mnode-client
if the value is not already populated.
c. Click
Authorize
to begin a session.
d. Close the window.
4. Click
PUT /nodes/{hardware_id}
.
5. Click
Try it out
.
6. Enter the node asset id that you saved earlier in the
hardware_id
parameter.
7. Enter the following information in the payload:
Parameter
Description
assetId
The installation asset id (
id
) that you saved in step
1(f).
bmcIp
The BMC IP address (
bmcAddress
) that you saved
in step 1(k).
bmcPassword
An updated password to log into the BMC.
bmcUsername
An updated user name to log into the BMC.
serialNumber
The chassis serial number of the hardware.
Example payload:
Summary of Contents for HCI
Page 95: ...NetApp HCI Resources page...
Page 308: ......