![NetApp HCI Manual Download Page 206](http://html1.mh-extra.com/html/netapp/hci/hci_manual_1669957206.webp)
Find more information
•
NetApp Element Plug-in for vCenter Server
•
Upgrade storage firmware
Starting with Element 12.0 and management services version 2.14, you can perform
firmware-only upgrades on your H-series storage nodes using the NetApp Hybrid Cloud
Control UI and REST API. This procedure does not upgrade Element software and
enables you to upgrade storage firmware outside of a major Element release.
What you’ll need
•
Admin privileges
: You have storage cluster administrator permissions to perform the upgrade.
•
System time sync
: You have ensured that the system time on all nodes is synced and that NTP is
correctly configured for the storage cluster and nodes. Each node must be configured with a DNS
nameserver in the per-node web UI (
https://[IP address]:442
) with no unresolved cluster faults
related to time skew.
•
System ports
: If you are using NetApp Hybrid Cloud Control for upgrades, you have ensured that the
for more information.
•
Management node
: For NetApp Hybrid Cloud Control UI and API, the management node in your
environment is running version 11.3.
•
Management services
: You have updated your management services bundle to the latest version.
For H610S storage nodes running Element software version 12.0, you should apply D-patch
SUST-909 before you upgrade to storage firmware bundle 2.27. Contact NetApp Support to
obtain the D-patch before you upgrade. See
Storage Firmware Bundle 2.27 Release Notes
.
You must upgrade to the latest management services bundle before upgrading the firmware
on your storage nodes. If you are updating your Element software to version 12.2, you need
management services 2.14.60 or later to proceed.
•
Cluster health
: You have run health checks. See
Run Element storage health checks prior to upgrading
•
Updated BMC for H610S nodes
: You have upgraded the BMC version for your H610S nodes. See
release notes and upgrade instructions
For a complete matrix of firmware and driver firmware for your hardware, see
(login required).
Upgrade options
Choose one of the following storage firmware upgrade options:
•
Use NetApp Hybrid Cloud Control UI to upgrade storage firmware
•
Use NetApp Hybrid Cloud Control API to upgrade storage firmware
Summary of Contents for HCI
Page 95: ...NetApp HCI Resources page...
Page 308: ......