CHAPTER 1 MAINTENANCE SERVICE FEATURES
– 16 –
NWA-008847-001 Rev.3.0
a6ch1001.fm
NOTE 1:
Even if the external alarm is set as MN or MJ alarm for system initialized (1st data=01), no
alarm is output in the case of Power On, Reset key operated, initialization from the MAT/CAT,
and initialization by MP SW3 switch selection.
NOTE 2:
The External Alarm Kind for “Number of faulty trunks was more than predetermined number”
is fixed as MN or MJ by CM42>06, 07. When CM42>06, 07 is assigned, the 2nd data of CMEA
Y=2 simply means the fault information is to be registered into Fault Memory. In this case, Ex-
ternal Alarm kind cannot be changed.
NOTE 3:
The External Alarm Kind for “Number of lockout stations was more than predetermined num-
ber” is fixed as MN. The 2nd data of CMEA Y=2 simply means the fault information is to be
registered into Fault Memory.
In this case, External Alarm Kind cannot be changed.
NOTE 4:
If Virtual CSH for WLAN detects a communication failure between the CSH and SIP server, by
a health check, the fault kind “2B” is registered as fault information.
NOTE 5:
The fault information of the fault kind “2C”/“3C” is also registered when a fault has occurred/
been restored in OAI mode. The fault information to be registered then is as follows.
[Series 3600 software required]
• The fault kind “2C” (LAN application fault occurred)
a) ABOUT/RLRQ (U-ABOUT/RLRQ reception)
b) Fault detection by healthcheck (healthcheck IP T.O.)
• The fault kind “3C” (LAN application returned to normal condition)
a) Association establishment (AARQ reception)
Continued on next page
DESCRIPTION
DATA
Assign the number of stations in line
lockout to give MN (minor) alarm.
Assign the number of detected faulty
trunks to give MN (minor) alarm.
[Australia Only]
Assign the number of detected faulty
trunks to give MJ (major) alarm.
[Australia Only]
(1)
(2)
(1)
(2)
(1)
(2)
01
01-99: Number of lockout stations
06
01-99: Number of Line Fault trunk
07
01-99: Number of Line Fault trunk
END
D
CM42
OCTOBER/14/2005
FAULT MESSAGE
Summary of Contents for UNIVERGE NEAX 2000 IPS
Page 1: ...NWA 008847 001 ISSUE 3 0 Maintenance Manual...
Page 10: ...iv NWA 008847 001 Rev 3 0 a6toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Page 124: ...114 NWA 008847 001 Rev 3 0 a6ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006...
Page 244: ...234 NWA 008847 001 Rev 3 0 a6ch2001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006...
Page 262: ...252 NWA 008847 001 Rev 3 0 a6ch3001 fm THIS PAGE LEFT BLANK INTENTIONALLY...