CHAPTER 2 TROUBLESHOOTING
– 146 –
NWA-008847-001 Rev.3.0
a6ch2001.fm
Remedial Action on Each Fault Kind
NOTE:
While authenticating the license, Fault Kind Number 17 will be displayed in the following con-
ditions.
• When entering the correct activation code.
• When entering the wrong activation code.
• When initializing the system after registering the Key FD with the registered old activation
code.
• When the formal activation code is not registered within 5 days after the preliminary activa-
tion code (4320) is registered.
Continued on next page
FAULT
KIND
NUMBER
FAULT CONTENT
FAULT INFORMATION
REMEDIAL ACTION
17
Key FD Activation
NOTE
3: XX XX XX XX
Result (See below.)
Result: ID Code Error
Enter the correct acti-
vation code.
Check the capitals,
symbol and register
the preliminary acti-
vation code or the
formal activation
code again.
Access to the Soft-
ware License Activa-
tion Center.
Obtain the activation
code and register to
the PBX.
20
DTI line failure
3:
XX XX XX XX
Fault Details Kind
(See below.)
Fault Detail Kind 00: PCM loss
Check the DTI cable con-
nection.
1
2
3
FAULT DIAGNOSIS AND TROUBLESHOOTING
Summary of Contents for UNIVERGE NEAX 2000 IPS
Page 1: ...NWA 008847 001 ISSUE 3 0 Maintenance Manual...
Page 10: ...iv NWA 008847 001 Rev 3 0 a6toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Page 124: ...114 NWA 008847 001 Rev 3 0 a6ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006...
Page 244: ...234 NWA 008847 001 Rev 3 0 a6ch2001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006...
Page 262: ...252 NWA 008847 001 Rev 3 0 a6ch3001 fm THIS PAGE LEFT BLANK INTENTIONALLY...