Remedial Action on Each Fault Kind
Continued on next page
FAULT
KIND
NUMBER
FAULT CONTENT
FAULT INFORMATION
REMEDIAL ACTION
12
CS/ZT Fault
occurred
Fault Kind 05: SYS-ID upload failure
Check the LEN No.
of the CS/ZT with
SYS-ID is correct by
CMAE Y=00>02
Make the CS/ZT
busy or idle condi-
tion by CME5 Y=3.
Turn OFF and ON
the CS/ZT power
switch.
Fault Kind 06: SYS-ID download
failure
When input the SYS-
ID from MAT, check
if the number is cor-
rect.
Check the CS/ZT is
CS/ZT without SYS-
ID
Make the CS/ZT
busy or idle condi-
tion by CME5 Y=3.
Turn OFF and ON
the CS/ZT power
switch.
Fault Kind 07: CS/ZT make busy
failure
Make the CS/ZT busy or
idle condition by CME5
Y=3.
Fault Kind 08: CS/ZT data load
failure
Make the CS/ZT
busy or idle condi-
tion by CME5 Y=3.
Turn OFF and ON
the CS/ZT power
switch.
1
2
3
1
2
3
4
1
2
FAULT DIAGNOSIS AND TROUBLESHOOTING
Summary of Contents for UNIVERGE NEAX 2000 IPS
Page 1: ...NWA 008847 001 ISSUE 3 0 Maintenance Manual...
Page 10: ...iv NWA 008847 001 Rev 3 0 a6toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Page 124: ...114 NWA 008847 001 Rev 3 0 a6ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006...
Page 244: ...234 NWA 008847 001 Rev 3 0 a6ch2001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006...
Page 262: ...252 NWA 008847 001 Rev 3 0 a6ch3001 fm THIS PAGE LEFT BLANK INTENTIONALLY...