CHAPTER 2 TROUBLESHOOTING
– 179 –
NWA-008847-001 Rev.3.0
a6ch2001.fm
Remedial Action on Each Lamp Status
Continued on next page
CARD NAME
LAMP
STATUS
FAULT
CONTENT
REMEDIAL ACTION
PN-CFTC/
PN-CFTC-A
(CFT)
RUN lamp is not
on
Abnormal opera-
tion of CFT card
Confirm the programming data:
CM05 Y=0/Y=1, CM07 Y=01.
Check to see if the SENSE switch is
set as per the AP Number (04-15,
20-31) assigned by CM05 Y=0.
Reset the MB switch.
(Down Up Down)
If the fault cannot be cleared,
replace the card.