CHAPTER 2 TROUBLESHOOTING
– 196 –
NWA-008847-001 Rev.3.0
a6ch2001.fm
Remedial Action on Each Lamp Status
Continued on next page
CARD NAME
LAMP
STATUS
FAULT
CONTENT
REMEDIAL ACTION
PN-SC00
(CCH)
RUN lamp is not
flashing
Abnormal opera-
tion of CCH card
Confirm the programming data:
CM05 Y=0.
Check to see if the SENS switch is
set as per the AP Number (04-15,
20-31) assigned by CM05 Y=0.
Reset the MB switch.
(Down Up Down)
If the fault cannot be cleared,
replace the card.
LC lamp is not on CCH link connec-
tion failure
Check the status of the local-office side
line or the remote-office side line.
PN-SC01
(DCH)
RUN lamp is not
flashing
Abnormal opera-
tion of DCH card
Confirm the programming data:
CM05 Y=0.
Check to see if the SENS switch is
set as per the AP Number (04-15,
20-31) assigned by CM05 Y=0.
Reset the MB switch.
(Down Up Down)
If the fault cannot be cleared,
replace the card.
LC lamp is not on DCH D-channel
link connection
failure
Check the status of the local-office side
line or the public network side line.
1
2
3
4
1
2
3
4
FAULT DIAGNOSIS AND TROUBLESHOOTING
Summary of Contents for UNIVERGE NEAX 2000 IPS
Page 1: ...NWA 008847 001 ISSUE 3 0 Maintenance Manual...
Page 10: ...iv NWA 008847 001 Rev 3 0 a6toc001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Page 124: ...114 NWA 008847 001 Rev 3 0 a6ch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006...
Page 244: ...234 NWA 008847 001 Rev 3 0 a6ch2001 fm THIS PAGE LEFT BLANK INTENTIONALLY JULY 01 2006...
Page 262: ...252 NWA 008847 001 Rev 3 0 a6ch3001 fm THIS PAGE LEFT BLANK INTENTIONALLY...